CONFIGURATION
TYPICAL WIRING
1F83-0471/1F85-0471
1F83-0422/1F85-0422
1F83-0471/1F85-0471 INSTALLER/CONFIGURATION MENU (cont.)
CONFIGURATION MENU
Menu
Ref. HP SS
Press
Button
Displayed
Factory (Default)
Press or to
select from listed options COMMENTS
17 16 16 MENU (On) AS Cool OFF Automatic Schedule for cool mode. NA 1F83. NA to Heat only system.
18 17 _ MENU (On) FA Heat OFF Fast Heat option may be disabled by selecting OFF.
NA to SS config. NA to Cool only system.
19 18 _ MENU (On) FA Cool OFF Fast Cool option may be disabled by selecting OFF.
NA to SS config. NA to Cool only system
20 19 17 MENU CA (OFF) On Selects active Comfort Alert On or OFF.
Requires CA II Module. (1F85CA only)
21 20 18 MENU (On) dS OFF Selects Automatic daylight Savings Time option On or OFF.
NA 1F83.
22 21 19 MENU (OFF) Change Filter On Selects Filter Change-out Indicator On or OFF.
MENU Change Filter (200 h) 25-1975 h Change Filter time in 25 hour increments. This menu only appears
if On is selected in above.
23 22 20 MENU (o) On Cool Heat On (b) Selects operation of the reversing valve terminal (O/B) output
as an O or B terminal.
24 23 21 RUN
SCHED
Returns to Normal Operation
Heat Pump 1
(HP1)
O
Energized in
Cool Mode
B
Energized in
Heat, Off,
Emergency
Mode
No
Output
Heat and
Cool Mode
1st Stage
(Compressor)
Blower/
Circulator
Fan Energized
on Call for
Heat or Cool.
Set Elect/Gas
Option for
Emergency
Mode
Heat Mode
2nd Stage.
Emergency
Mode 2nd
Stage
Emergency
Mode
1st Stage
Optional*
24 Volt
(Com-
mon)
Fault Indicator
or
System
Malfunction
Switch
24 Volt
(Hot)
Cool
System
Y
W/E
C
L
RC
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
24 Volt
(Hot)
Heat
RH
Jumper
Y2
W2
G
Jumper
Comfort Alert II Module
or Similar System
Malfunction Module
O/B
Heat Pump Systems
NOTE: If your system
does not provide an
E connection, jumper
W2 to W/E to use the
Auxiliary Heat in the
Emergency Mode.
* Common connection
required for fault or
malfunction indication.
TYPICAL WIRING DIAGRAMS